Introduction

Use this guide to replace, repair, or clean a heating surface on a Corning PC-351 laboratory hot plate. The heating surface is the metal plate through which the heating coil conducts heat through to warm any object placed on it. Over time this plate may become warped through repeated usage, dented by any impacts, or soiled by dirt and chemicals. In this case, removing the heating plate from the device is necessary for cleaning or installing a new plate to prevent uneven heating.

Safety first! Before proceeding with this guide, please ensure the hot plate is unplugged and cooled down. In addition, ensure all the dials on the device are set to 'off.' You don't need special tools or technical knowledge to complete this repair.

  1. cAsxdGWpOgGKUQLb
    cAsxdGWpOgGKUQLb
    raMWlaBGyLalAHkm
    • Unplug the hot plate and ensure it's fully cooled before beginning.

    • Flip the hot plate over so that the heating surface is facing downwards.

  2. c4cFM2soIuBBGfNy
    • Remove the four bottom panel 3 x 12 mm screws with a Phillips #2 screwdriver.

    • Detach the bottom panel.

  3. VbPvIXDMHiMSYGPS
    VbPvIXDMHiMSYGPS
    HpOSgC3tJYPOoExI
    • Remove the four heating surface 3 x 16 mm screws with a Phillips #2 screwdriver.

  4. EEKpFWFL3C3IDUtc
    EEKpFWFL3C3IDUtc
    VYNo64HZQIfBJaoR
    • Detach the heating surface lead wire connectors (the white wires) from the power supply with a pair of needle nose pliers.

  5. 1XPAORcyGhS46jMu
    • Separate the hot plate body from the damaged or dirty heating surface and place the new heating surface below the body.

  6. MoIVtDouv4B5LUPi
    MoIVtDouv4B5LUPi
    YPX1UI5wyegEYrWA
    TiifRqYDg3bCuZID
    • Connect the new hot plate heating surface lead wire connectors (the white wires).

    • Carefully thread the left lead wire connector below the heating coil.

    • You will need to feed the left lead wire below the heating coil for it to reach the connection

  7. LUCHQd46EVKtXMQO
    • Fasten the four hot plate heating surface 3 x 16 mm screws using a Phillips #2 screwdriver.

  8. 5JCD5mBYCRrYBcjX
    • Attach the bottom panel and fasten the bottom panel 3 x 12 MM screws using a Phillips #2 screwdriver.

  9. GcaFhOeELXEC4QTq
    GcaFhOeELXEC4QTq
    nTiI3k5xbPHbCujv
    • Flip the hot plate right side up, so that the heating surface is now facing upwards.

Conclusion

To reassemble your device, follow instructions after step 6. Thank you for reading our guide, and we hope you found it helpful!