Introduction
This guide will show you how to replace the door switch for the Sharp Microwave so that it will not turn on when the door is opened.
Tools
-
-
Sharp microwave running with door open
-
Problem with the hardware interlock switches triggered by the door latch
-
Sharp model R-248BS
-
-
-
Side screw
-
...and 4 screws in the back
-
Star screws need T15X4 or equivalent. A flathead can be used in a pinch.
-
Remove the screws
-
-
-
Remove the case, should slide out with a little bit of effort.due to notches in the frame on the front top left ( when looking from the back).
-
-
-
Now we will identify the switches
-
The lower two switches
-
... and the upper switch
-
Upper switch faulty
-
-
-
Top switch appears loose
-
Replace and reinstall
-
Angled reinsertion to line up hole with plastic support
-
To reassemble your device, follow these instructions in reverse order.
One comment
Some Sharp Microwaves use different Torx screws. The T15 didn't fit the screws on my model, it appears to be the security version of the T15. I suggest getting a set such as the Mako instead.