Introduction

Here's how to fix one of the most common failures on ghd straighteners

  1. JYix2FndvBGJnWNl
    JYix2FndvBGJnWNl
    umfZvFbuAQpQuAvK
    • Lightly lift the round covers using your finger to create a small opening.

    • Insert a thin flat screwdriver, or a lever if you have one in this opening.

    • Lift by trial and error to avoid breaking the teeth of these covers which are fragile. If they break, don't panic, you can glue them.

  2. OTyvGuLMFrJl3fOG
    OTyvGuLMFrJl3fOG
    Am2wcEysvfMfivWO
    wCC3rWorBJZaXPln
    • Sometimes these screws are mounted with screw glue. It is best to have two screwdrivers, including a small one for better control.

    • Start by unscrewing the screw by having the first screwdriver fixed on one side, and the other unscrewing on the other side.

    • screw it out, push the shaft and take it out.

  3. oQQEX6EdpWhUKiWd
    oQQEX6EdpWhUKiWd
    wMaQKPa3kNMKcZpR
    • Push the plastic axle with your screwdriver and take it out.

    • Remove the spring.

  4. FX3aMhCrMCVPH6I5
    FX3aMhCrMCVPH6I5
    giVidSU6VMDcsMO6
    • Remove the two screws from the button side cover.

    • Remove the cover equipped with the button.

    • The electronic card is now accessible. You can test the thermal fuse if you wish.

  5. afvWpa5qJ6rIJ5iI
    afvWpa5qJ6rIJ5iI
    MmRR6ZgYBUMIRRWN
    tSVsLo2aOCfWDKk5
    • Unscrew the 4 screws that hold the plate to the electronic board.

    • The thermal fuse is now accessible.

    • To remove the HS fuse, slightly pull out its cables as shown in the photo.

    • Using small pliers, scissors or nail clippers, cut the two cables.

    • You can now easily pull out the fuse head and cables on the other side.

  6. Dl4t2KIEcL6xgEO1
    Dl4t2KIEcL6xgEO1
    snIcRNgLRraeKYuX
    JAPHZdggNnTORqAy
    • Insert the 2 cables of the new thermal fuse.

    • Lift the tab and insert the fuse head.

    • Pull the two cables and press on the head to firmly press the fuse against the ceramic plate.

  7. XZ3Yf55jNOHxeVqx
    XZ3Yf55jNOHxeVqx
    jAmJT6FOnSbC34Qm
    QsQLJOl43likQPNM
    • Refit the plate on the electronic card using the 4 screws.

    • Do not forget to put the silicone part, which protects the electronic card against heat.

    • Refit the cover fitted with the button using the two screws.

  8. LjD6keEFvaRQGibe
    • Connect the straightener cable

    • You can now test the operation.

    • If you have a thermometer, the temperature should be between 180°C and 190°C. If you don't have one, turn on the straightener and let it heat up for 5 minutes to make sure everything is okay.

  9. lNtPBcthBVDiIJfB
    lNtPBcthBVDiIJfB
    YJYZ3DmqpDZCEm2o
    doauNEsS61AN1FWI
    • You can now reassemble everything:

    • First the spring, then the plastic axle, then the metal axle and finally the screws/washer and covers.

    At this point I wondered how the spring clipped in but don't worry it lies on top of the wires and when you put the little plastic axle in and the screws it works...Great guide, thank you

    Michael Dodd -

Conclusion

To reassemble your device, follow the steps in reverse order.

Dr-lisseur.com

Member since: 14/07/22

153 Reputation

One comment

Bonjour j'ai un lisseur GHD le model est 4.2B , je l'ai brancher j'ai entendu 2 bip et plus rien , pensez-vous que c'est le fuisible qui est HS ? Cordialement

Laurent -