Introduction
Safety notice:
The glass container is under vacuum and can implode. Therefore, wear gloves and safety goggles when handling !
Tools
-
-
Turn the jug upside down
-
The black base is screwed into the housing. Unscrew to the left.
-
Reach into the jug while wearing a glove
-
Turn the jug upside down and carefully remove the glass body and place it with the opening on a soft surface. The fused nozzle used for pumping can break off easily.
-
The glass body is available as a spare part (part 00441154, approx. 22 EUR incl. seal)
-
-
-
The seal is loosely inserted in the housing. It is usually the cause for to leak out of the thermos housing.
-
The seal is available as a spare part (00426033, approx. 5 EUR).
-
For further disassembly loosen the 3 Torx T10 screws (plastic thread ca 3.2 x 15)
-
Press on the black plastic point and pull apart the upper and lower part
-
-
-
The handle is attached to the housing with a PH2 screw.
-
If the handle is loose, tighten carefully so that the thread in the plastic does not tear out. The handle is not available as a spare part.
-
-
-
Thoroughly clean or replace the gasket before reassembly.
-
Use a piece of foam between the base and the glass container to apply a little more pressure to the seal, without damaging the glass container
-
Follow these steps in revere order to reassemble your device