Introduction

This guide shows how to remove the heating element and/or the thermostat of your Aroma ARC-914SBD rice cooker. The process of removing either or both parts is the same; therefore, we have combined them into one guide. First, the device will have to be opened. Please see the guide for lid replacement to start the process of opening the device.

  1. wqhT5jLhyODmTQ4g
    wqhT5jLhyODmTQ4g
    TyiVxMUAnHLqGEQS
    • The first step is removing the condensation catcher in order to reach the control panel. We do this by pinching the condensation catcher as shown, on both sides and pull the condensation catcher away from the cooker.

  2. UEkHdOhvi3XAhKFB
    • Once the condensation catcher has been removed, set it aside for reassembly later.

    • Now make sure you have a a Phillips head screwdriver, size PH2. This tool will allow you to remove the screw that was behind the condensation catcher.

  3. 35WVoiGnupRHodVJ
    35WVoiGnupRHodVJ
    TIZb6h31qt3AmyBZ
    • Gently remove the piece that was held in place by the screw, you do this by pulling out from the top, then pulling up. This will expose the hinges for the lid.

  4. Br3TFcyVKWJwPtbu
    Br3TFcyVKWJwPtbu
    caPIqRmtZLb6UHC3
    YIlx2MniwNoIM6hK
    • To remove the hinge, gently rotate the bottom of the rod upwards, then push inward to pull the rod out. Repeat the process for each rod. This will allow the lid to be removed.

  5. iSVfrMpcTu2TCoAj
    iSVfrMpcTu2TCoAj
    nRg4WkmmkXqHNCxE
    • Locate the piece on the black plastic trim that is opposite from where the hinges were. Carefully, pry this piece from the bottom to get the tab from behind the stainless steel to in front of the steel as shown.

  6. FTYTRiNlJM1Etn2D
    FTYTRiNlJM1Etn2D
    GS2F4QWNj4d2KPVc
    • Next, you must remove the upper black trim which is connected to the inside liner with tabs. To do this you must hold the interior walls still, while rotating the trim so that the tabs line up with the slots. (tabs cannot be seen at this point, pics are to give you an idea of what you cannot see inside the device)

    On my ARC-914SBD there is a single square tab that locks into the plastic rim. You can see it through the opening where the hinge was (you can also see the slots you need to rotate past to separate the trim). To see it I had to rotate the lid latch piece (along with the interior wall) counter clockwise past the power button panel. I pulled that tab back so the trim was not locked into the interior wall. Even still it's been impossible to hold the interior wall in place. I suspect there may be another tab that I cannot rotate to. I have a good photo, but don't see a way to send it.

    So now I'm stuck on this step. Not being able to release the trim from the interior wall!!

    Mr Noah Ittall -

  7. 6xbvhAFVPJDHwaVg
    6xbvhAFVPJDHwaVg
    rIZU1Ffi2tXPSlwN
    • Using a Phillips head screwdriver, size PH2, remove the screws from the control module to expose wired connections.

  8. Ji2rZbf21DsbcsDN
    • Unplug thermostat from control module

  9. qNhurJUMlPvAE14G
    • Remove red and blue wires from heating element to fully detach from control module. This is done by removing the screws on the heating element terminals using a Phillips head screwdriver, size PH2.

  10. Kvq5FYFjMVgeduaB
    Kvq5FYFjMVgeduaB
    RFElytFek4DoNLwa
    • Again, using a Phillips head screwdriver, size PH2, remove the three screws holding the heating element assembly to the bowl. This will remove the heating element and the thermostat.

    Once removed the termostad what?

    ale espinal -

Conclusion

To reassemble your device, follow these instructions in reverse order.

Brandon Nieves

Member since: 04/09/15

956 Reputation

2 comments

Where do you get a replacement thermostat?

4forums -

https://www.amazon.com/Aexit-Terminal-Co... or https://www.aliexpress.us/item/225580067... or try googling some combinations of the keywords: 2 pin/wire rice cooker temperature/thermostat magnetic probe/sensor replacement

JAR -